Part Number 30-2310 INLINE WIDEBAND UEGO CONTROLLER Figure 1. Wiring Schematic Inline Wideband UEGO Controller Parts 1 x
Page 2 RED - Connect to a switched, fused (5A) 12 volt power source. BLACK – Connect to a clean power ground. WHITE - Connect to Lambda + Input. BROW
Page 3 ZIP TIES Figure 3. Inline Wideband UEGO Controller Mounting Indicator Lights The Inline Wideband UEGO Controller has two indicat
Page 4 UEGO Analog Output The analog output from the Inline Wideband UEGO controller is a linear dc voltage signal that varies from 0.5 Vdc at 8.5:1
Page 5 Voltage AFR Voltage AFR Voltage AFR Voltage AFR 0.00 8.43 1.40 10.64 2.81 13.99 4.21 17.31 0.16 8.43 1.56 11.02 2.96 14.34 4.37
Page 6 Inline Wideband UEGO/AEM F/IC Configuration With an FIC calibration open, go to Setup>Aux Gauge, and complete the Aux gauge setup window as
Page 7 Figure 6. PC Data Viewer The grey wire from the UEGO Controller outputs the data stream in an RS232 serial format. To connect to the pc/l
Page 8 Specifications UEGO Controller Supply Current (nominal, peak) 1.3A, 2.7A peak Differential Analog Outputs 1 Measuring Range: UEGO 8.5:1 to