Inline Wideband UEGO/AEM F/IC Configuration
With an FIC calibration open, go to Setup>Aux Gauge, and complete the Aux gauge
setup window as shown below in Figure 5.
Figure 5. F/IC Aux Gauge Setup
Connect the WHITE Analog Output + wire to the Aux Gauge input and the BROWN
Analog Output – wire to the sensor ground. Table 5 below lists the Lambda and Sensor
ground pin locations for the different FIC part numbers.
AEM F/IC P/N Lambda Pin Sensor GND Pin
30-1910(X) Pin 18 of 22-pin connector Pin 5 of 22-pin connector
30-1930(X)
Pin 18 of 22-pin connector
Pin 20 of 20-pin connector
Pin 5 of 22-pin connector
Table 5. F/IC Pin Locations
Displaying Data with a PC/Laptop
Real time AFR data can also be viewed via a pc/laptop using an RS232 serial port
connection. Download the data viewer program and instructions from the AEM
Performance Electronics forum at www.aemelectronics.com
. . See figure 6.