Page 148 of 279 EMS-4 Install and Tuning Guide_Rev 1.6
Crank Fuel & Engine Start
Typical Start Setup Tab
Crank setup options
Crank Advance Desired ignition timing during cranking conditions
Crank Inject All When selected, all injector outputs will fire at the same time and inject fuel
using the pulsewidth values defined in the Initial Crank Pulse table.
Crank Min RPM The minimum engine speed before fuel and spark events are allowed.
Typically set to 50 RPM.
Crank Max RPM The maximum engine speed for cranking fuel and spark values. Varies but
usually set to 300 500 RPM.