Page 34 of 279 EMS-4 Install and Tuning Guide_Rev 1.6
Cam Sensor Input Cable End
Harness Connections
Cam Sensor Harness Connections
Cam Sensor Ground
28
White
Cam Sensor Mag Input
28
Green
Cam Sensor Hall
24
Black
+12 volts
24
Red
Cable Shield
---
Cam Sensor Mag Input, Green Connect to VR (+) signal (rising edge zero cross). Not used
for Hall sensor configurations.
Cam Sensor Hall, Black Connect to Hall sensor signal. Not used for VR sensor
configurations.
+12 volts, Red Connect to Hall sensor reference voltage. Not used for VR sensor
configurations. Insulate if not using (hot at key-on).
Cam Sensor Ground, White Connect to Crank sensor VR (-) or Hall sensor signal ground
Vehicle Speed Sensor (VSS)
Vehicle Speed Sensor Basics